Page 10 Copyright © 2007 Proxim Wireless
Step 3: Assemble the Cable
You will be attaching an outdoor-rated 24 AWG CAT5 cable (diameter .114
to .250 inches/2.9 to 6.4 mm) (not provided) to the Power-over-Ethernet
port on the back of the unit and weatherproong the assembly later in the
installation procedure. First, you must construct the cable and assemble
the weatherproong cable covers as described in the following steps. Proxim
greatly simplies this assembly process by offering pre-assembled CAT5 cable
kits in 25m, 50m, and 75m lengths (part numbers 69819, 69820, and 69821,
respectively).
Slide the sealing nut (A) over the bare end of the CAT5 cable.1.
Slide the lock nut (B) over the bare end of the CAT5 cable.2.
Slide the sealing cap (C) over the bare end of the CAT5 cable. Make sure 3.
the red rubber gasket is inside the cap.
Apply two wraps of 0.5” wide Teon tape (not supplied with unit) around 4.
the threads of the lock nut (B) that will go inside the sealing cap.
Thread the lock nut (B) onto the sealing cap (C), and hand tighten.5.
Terminate the RJ45 connectors (D) to both ends of the CAT5 cable; test for 6.
proper wiring (using a straight-through cable).
Notes:
The cable must feed through all parts of the weatherproof cap before the ▪
RJ45 is crimped on the outdoor Ethernet cable.
The cable between the power injector and the unit must be a straight- ▪
through Ethernet cable (without crossover).
Due to variance in CAT5 cable diameter, termination techniques of the ▪
installer, and the application of proper tightness of the connectors, it is
strongly recommended that all cable connectors are secured by external
weatherproong. This process will be described in Step 10: Weatherproof
the Connectors.